Research Article
Effects of Impeller Diameter on High-Speed Rescue Pump
Table 1
Main parameters of original high speed rescue pump.
| GPQ200-300 |
| (m3/h) | (m) | (rpm) | |
| 200 | 300 | 6000 | 71.46 |
| Impeller | Diffuser vane |
| /mm | 65 | /mm | 253 | /mm | 125 | /mm | 360 | /mm | 248 | /mm | 310 | /° | 32 | /° | 11.4 | /mm | 15 | /mm | 22 | γ/° | 135 | /mm | 30 | | 7 | | 9 |
|
|