Research Article
Effects of the Slot Harmonics on the Stator Current in an Induction Motor with Bearing Fault
Table 2
The experimental results of healthy and faulty motors under several different load conditions.
| State | | | | | | | | | |
| Fault | 23.8500 | 85.8600 | Calculated/Hz | 135.9279 | 159.7779 | 627.2721 | 727.4079 | 775.1421 | 875.2779 | Estimated/Hz | 135.9463 | 159.6451 | 626.4210 | 727.1767 | 774.5743 | 874.6624 | Amplitude/dB | −66.9323 | −69.9651 | −72.6639 | −74.7578 | −77.3310 | −73.2667 |
| Health | 23.8500 | — | Amplitude/dB | −76.2459 | −77.6033 | −81.5884 | −82.4756 | −82.0215 | −82.0451 |
| Fault | 23.9655 | 86.2758 | Calculated/Hz | 136.3437 | 160.3092 | 630.5523 | 730.6881 | 779.1384 | 879.2742 | Estimated/Hz | 136.3277 | 160.1696 | 629.2343 | 730.6576 | 777.1015 | 878.1433 | Amplitude/dB | −67.8734 | −75.5752 | −77.3139 | −78.9183 | −81.8125 | −77.7823 |
| Health | 23.9655 | — | Amplitude/dB | −79.1248 | −84.4931 | −85.4721 | −85.9430 | −85.1713 | −85.4535 |
| Fault | 24.0907 | 86.7265 | Calculated/Hz | 136.7944 | 160.8851 | 634.1080 | 734.2438 | 783.4703 | 883.6061 | Estimated/Hz | 136.7569 | 160.6941 | 633.7643 | 733.6617 | 783.1097 | 882.5779 | Amplitude/dB | −66.9565 | −80.2746 | −77.7492 | −78.7337 | −81.7378 | −77.8168 |
| Health | 24.0907 | — | Amplitude/dB | −84.4098 | −85.5045 | −85.3693 | −85.1180 | −85.2143 | −85.2862 |
| Fault | 24.1980 | 87.1128 | Calculated/Hz | 137.1807 | 161.3787 | 637.1553 | 737.2911 | 787.1829 | 887.3187 | Estimated/Hz | 137.1384 | 161.2186 | 637.2929 | 736.4750 | 788.3072 | 888.9675 | Amplitude/dB | −70.0095 | −77.2724 | −77.8660 | −79.1447 | −81.7262 | −78.4580 |
| Health | 24.1980 | — | Amplitude/dB | −78.0160 | −82.9799 | −85.0438 | −85.4245 | −85.2521 | −85.6223 |
|
|