Research Article

Effects of the Slot Harmonics on the Stator Current in an Induction Motor with Bearing Fault

Table 2

The experimental results of healthy and faulty motors under several different load conditions.

State

Fault23.850085.8600Calculated/Hz135.9279159.7779627.2721727.4079775.1421 875.2779
Estimated/Hz135.9463159.6451626.4210727.1767774.5743 874.6624
Amplitude/dB−66.9323−69.9651−72.6639−74.7578−77.3310−73.2667

Health23.8500Amplitude/dB−76.2459−77.6033−81.5884−82.4756−82.0215−82.0451

Fault23.965586.2758Calculated/Hz136.3437160.3092630.5523730.6881779.1384879.2742
Estimated/Hz136.3277160.1696629.2343730.6576777.1015878.1433
Amplitude/dB−67.8734−75.5752−77.3139−78.9183−81.8125−77.7823

Health23.9655Amplitude/dB−79.1248−84.4931−85.4721−85.9430−85.1713−85.4535

Fault24.090786.7265Calculated/Hz136.7944160.8851634.1080734.2438783.4703883.6061
Estimated/Hz136.7569160.6941633.7643733.6617783.1097882.5779
Amplitude/dB−66.9565−80.2746−77.7492−78.7337−81.7378−77.8168

Health24.0907Amplitude/dB−84.4098−85.5045−85.3693−85.1180−85.2143−85.2862

Fault24.198087.1128Calculated/Hz137.1807161.3787637.1553737.2911787.1829887.3187
Estimated/Hz137.1384161.2186637.2929736.4750788.3072888.9675
Amplitude/dB−70.0095−77.2724−77.8660−79.1447−81.7262−78.4580

Health24.1980Amplitude/dB−78.0160−82.9799−85.0438−85.4245−85.2521−85.6223