Research Article
Prediction Model of Mechanical Extending Limits in Horizontal Drilling and Design Methods of Tubular Strings to Improve Limits
Table 3
Values of the relevant parameters in a case study.
| Parameters | Values |
| Kick-off depth () | 2500 m | Build-up rate () | 6°/30 m | Inner diameter of wellbore () | 311 mm | Outer diameter of tubular string () | 127 mm | Rated pick-up force () | 3000 kN | Rated torque () | 50 kN·m | Threshold axial force for rock breaking () | 50 kN | Threshold torque for rock breaking () | 5 kN·m |
|
|