Research Article

Design and Steady-State Performance of a Novel Winding Type Permanent Magnet Coupling with Slip Power Recovery Function

Table 3

Comparison of effective back-EMF.

Slip speed (r/min)Effective back-EMF (V)
2D FEAExperimental

002
1008.68
20017.216.3
30025.624.4
40034.232.5
50042.840.8