Nominal properties of rubber bearings.

Isolator Type [kN] [kN] [kN/mm] [kN/mm] [mm] [mm] [mm] [mm] [mm] [kg]S1S2

SI-S 600/168101054100.6781360016826831885043518.13.45
SI-S 650/180126062600.7485465018027732770050717.53.50
SI-S 800/1803400132801.12150680018028134185083519.54.33

= maximum vertical seismic load; = maximum vertical design load in Ultimate Limit State (ULS); = effective lateral stiffness; = vertical stiffness; = diameter; = total rubber thickness; = total height (not including anchor plates); = total height (including anchor plates); = side length of anchor plates; = weight without anchor bolts; = primary shape factor; = secondary shape factor.