Research Article
Base Isolation for Seismic Retrofitting of a Multiple Building Structure: Design, Construction, and Assessment
Table 4
Acceptance tests results on rubber bearings.
| N. | Isolator Type | Vertical stiffness [kN/mm] | Dynamic shear modulus [MPa] | Static shear modulus [MPa] | Viscous damping [%] |
| 1 | SI-S 800/180 | 1508 | 0.30 | 0.46 | 16.8 | 2 | SI-S 800/180 | 1524 | 0.31 | 0.46 | 16.2 | 3 | SI-S 800/180 | 1501 | 0.31 | 0.46 | 16.7 | 4 | SI-S 800/180 | 1512 | 0.30 | 0.46 | 16.5 | 5 | SI-S 650/180 | 862 | 0.33 | 0.45 | 16.2 | 6 | SI-S 650/180 | 828 | 0.30 | 0.42 | 17.3 |
|
|