Research Article

Base Isolation for Seismic Retrofitting of a Multiple Building Structure: Design, Construction, and Assessment

Table 4

Acceptance tests results on rubber bearings.

N.Isolator TypeVertical stiffness [kN/mm]Dynamic shear modulus [MPa]Static shear modulus [MPa]Viscous damping [%]

1SI-S 800/18015080.300.4616.8
2SI-S 800/18015240.310.4616.2
3SI-S 800/18015010.310.4616.7
4SI-S 800/18015120.300.4616.5
5SI-S 650/1808620.330.4516.2
6SI-S 650/1808280.300.4217.3