Research Article
Base Isolation for Seismic Retrofitting of a Multiple Building Structure: Design, Construction, and Assessment
Table 7
Force and displacements in isolation rubber bearings.
| ID | Device | Displ. (m) | Displ. (m) | | | ID | Device | Displ. (m) | Displ. (m) | | | kN | kN | kN | kN |
| 71 | SI-S 800/180 | 0.216 | 0.240 | 801.17 | 259.08 | 62 | SI-S 800/180 | 0.221 | 0.232 | 1141.3 | 593.45 | 59 | SI-S 650/180 | 0.216 | 0.224 | 693.18 | 330.63 | 56 | SI-S 650/180 | 0.221 | 0.224 | 908.92 | 542.60 | 26 | SI-S 600/168 | 0.216 | 0.215 | 703.17 | 383.69 | 14 | SI-S 600/168 | 0.221 | 0.203 | 847.99 | 524.82 | 28 | SI-S 600/168 | 0.216 | 0.198 | 776.74 | 457.23 | 15 | SI-S 650/180 | 0.221 | 0.206 | 940.08 | 573.77 | 29 | SI-S 600/168 | 0.216 | 0.199 | 863.94 | 544.40 | 104 | SI-S 800/180 | 0.221 | 0.247 | 1254.7 | 707.38 | 30 | SI-S 600/168 | 0.216 | 0.202 | 878.06 | 558.51 | 67 | SI-S 800/180 | 0.226 | 0.240 | 979.38 | 427.22 | 31 | SI-S 600/168 | 0.216 | 0.206 | 875.56 | 556.05 | 61 | SI-S 800/180 | 0.226 | 0.231 | 1134.6 | 582.11 | 32 | SI-S 600/168 | 0.216 | 0.211 | 591.79 | 282.16 | 55 | SI-S 650/180 | 0.226 | 0.224 | 856.27 | 487.12 | 95 | SI-S 650/180 | 0.216 | 0.226 | 660.95 | 298.34 | 2 | SI-S 600/168 | 0.226 | 0.209 | 714.49 | 388.75 | 107 | SI-S 800/180 | 0.216 | 0.250 | 881.35 | 339.25 | 4 | SI-S 600/168 | 0.226 | 0.198 | 850.78 | 525.00 | 63 | SI-S 800/180 | 0.219 | 0.232 | 947.71 | 402.43 | 5 | SI-S 600/168 | 0.226 | 0.199 | 951.86 | 626.05 | 19 | SI-S 600/168 | 0.219 | 0.203 | 802.85 | 481.21 | 6 | SI-S 650/180 | 0.226 | 0.202 | 1001.2 | 631.89 | 23 | SI-S 650/180 | 0.219 | 0.206 | 945.62 | 581.00 | 7 | SI-S 650/180 | 0.226 | 0.206 | 872.76 | 503.54 | 93 | SI-S 650/180 | 0.219 | 0.226 | 722.78 | 358.18 | 97 | SI-S 800/180 | 0.226 | 0.235 | 1068.3 | 515.74 | 105 | SI-S 800/180 | 0.218 | 0.247 | 1113.3 | 568.55 | 103 | SI-S 800/180 | 0.226 | 0.247 | 1101.6 | 549.39 |
|
|