Research Article

Performance Improvement of a Micro Impulse Water Turbine Based on Orthogonal Array

Table 8

Variance analyses in the working condition of 0.8.

Source of variationSum of squaresDegree of freedomMean squareCritical valueSignificance (relative)

A14.0627.034.90

B6.9323.472.42
C12.5426.274.37
D12.2526.134.27
E118.01259.0041.16
G41.38220.6914.43
Error5.2451.05
Total210.4117