Research Article

Multimodal Medical Image Registration Based on an Information-Theory Measure with Histogram Estimation of Continuous Image Representation

Table 3

Mean and standard deviations (Std.) of 20 registrations of the real 3D brain MR T1 and MR T2, MR T1 and MR PD, and MR T2 and MR PD images using three strategies (noise = 0.01). For each group of tests, the translations parameters in the -, -, and -axes were selected from the range 0–10 mm, and the rotations angles around the -, -, and -axes were selected from the range 0–10 degrees.

DatasetsMethodsMeanStd.Run time (s)

MR T1
and
MR T2
FCHE(0.24, 0.31, 0.33, 0.41, 0.49, 0.43)87
CHE(0.25, 0.32, 0.38, 0.43, 0.52, 0.46)1236
SH(0.28, 0.37, 0.40, 0.48, 0.56, 0.47)1.3
PZW(0.26, 0.32, 0.36, 0.46, 0.52, 0.45)1.43

MR T1
and
MR PD
FCHE(0.37, 0.35, 0.29, 0.47, 0.51, 0.50)86
CHE(0.38, 0.36, 0.28, 0.49, 0.55, 0.53)1203
SH(0.44, 0.41, 0.36, 0.54, 0.59, 0.54)1.25
PZW(0.42, 0.39, 0.33, 0.52, 0.56, 0.55)1.37

MR T2
and
MR PD
FCHE(0.35, 0.33, 0.34, 0.38, 0.41, 0.45)98
CHE(0.38, 0.36, 0.37, 0.42, 0.44, 0.46)1329
SH(0.39, 0.42, 0.33, 0.46, 0.52, 0.53)1.24
PZW(0.37, 0.39, 0.41, 0.41, 0.43, 0.48)1.4