Research Article
Proportional Load Sharing and Stability of DC Microgrid with Distributed Architecture Using SM Controller
Table 5
Voltage dynamic behavior for different values of
.
| Damping ratio | Sliding parameter (α, β) | Settling time | Response type |
| | (0.28, 100) | 0.05 s | Underdamped | (50 ms) | | (0.85, 100) | 0.04 s | Underdamped | (40 ms) | | (1.7, 100) | 0.03 s | Underdamped | (30 ms) | | (2.85, 100) | 0.02 s | Critically damped | (20 ms) |
|
|