Voltage dynamic behavior for different values of .

Damping ratio Sliding parameter (α, β)Settling timeResponse type

(0.28, 100)0.05 sUnderdamped
(50 ms)
(0.85, 100)0.04 sUnderdamped
(40 ms)
(1.7, 100)0.03 sUnderdamped
(30 ms)
(2.85, 100)0.02 sCritically damped
(20 ms)