Research Article
Study on the Rectification of Forebay in Pumping Station
Table 4
Section velocity uniformity.
| Program number | Condition | Velocity distribution uniformity (%) | A-B | C | E |
| 1 | Model test | 82.13 | 62.26 | 57.18 | Numerical simulation | 77.91 | 61.63 | 55.28 |
| 2 | Model test | 85.27 | 65.35 | 59.90 | Numerical simulation | 79.08 | 59.04 | 52.51 |
| 3 | Model test | 82.82 | 67.58 | 62.33 | Numerical simulation | 79.06 | 64.91 | 59.02 |
| 4 | Model test | 90.56 | 81.32 | 54.26 | Numerical simulation | 73.54 | 54.8 | 39.34 |
| 5 | Model test | 87.75 | 80.49 | 62.57 | Numerical simulation | 77.38 | 51.36 | 42.88 |
| 6 | Model test | 80.92 | 62.35 | 60.84 | Numerical simulation | 73.79 | 63.95 | 59.54 |
|
|