Research Article
Effect of Guide Vanes on Flow and Vibroacoustic in an Axial-Flow Pump
Table 1
Coefficient of variance corresponding to four monitoring points.
| ā | 0.8Qv | 1.0Qv | 1.3Qv |
| The max value at BPF | 37.97 kPa | 24.67kPa | 25.35 kPa | The min value at BPF | 33.84 kPa | 22.75kPa | 22.91kPa | The mean value at BPF | 35.44 kPa | 23.42kPa | 24.63kPa | The standard deviation | 1.77k Pa | 0.86kPa | 1.16kPa | Coefficient of Variance | 4.9% | 3.6% | 4.7% |
|
|