Research Article

Effect of Guide Vanes on Flow and Vibroacoustic in an Axial-Flow Pump

Table 1

Coefficient of variance corresponding to four monitoring points.

ā€‰0.8Qv1.0Qv1.3Qv

The max value at BPF37.97 kPa24.67kPa25.35 kPa
The min value at BPF33.84 kPa22.75kPa22.91kPa
The mean value at BPF35.44 kPa23.42kPa24.63kPa
The standard deviation1.77k Pa0.86kPa1.16kPa
Coefficient of Variance4.9%3.6%4.7%