Research Article

The Resonance Reliability and Global Sensitivity Analysis of Curved Pipe Conveying Fluid Based on TIS Method

Table 2

The relationship of four natural frequencies and velocities.

V (m/s)First (rad/s)Second (rad/s)Third (rad/s)Fourth (rad/s)

0165.46501.67992.991644.95
10165.41501.53992.831644.78
30165.01500.42991.511643.36
50164.22498.19988.881640.52
100160.65487.64976.431627.14