Research Article

Allocation of Distributed Energy Systems at District-Scale over Wide Areas for Sustainable Urban Planning with a MILP Model

Table 6

Assignment results of demand points to energy generation facilities according to requested energy types for Dc = 3 hm (300 m).

Demand pointsCandidate facilities
12345678

1Elec, therm, coolNo assignment

2No assignment

3ThermElecNo assignmentCool

4Elec, thermNo assignmentCool

5No assignment

6No assignmentElec, therm, cool

7No assignmentElec, therm, cool

8Elec, therm, coolNo assignment

9No assignment

10No assignment

11No assignmentElec, therm, cool

12No assignmentElec, coolTherm

13Elec, thermNo assignmentCool

14No assignmentElec, therm, cool

15No assignment

16Elec, therm, coolNo assignment

17No assignmentElec, therm, cool

18Elec, therm, coolNo assignment

19No assignmentElec, therm cool

20Elec, therm, coolNo assignment