Research Article
Deformation Forecast of Main Girder Enhanced by Stay Cable System with Unequal Interval Grey Model and Residual Composite Correction
Table 11
Fitting values of building settlement.
| Time/d | Measured values/mm | UIGM | Literature [11] model | Literature [12] model | UIGM-RCC | Fitting values/mm | Relative errors/% | Fitting values/mm | Relative error/% | Fitting values/mm | Relative error/% | Fitting values/mm | Relative error/% |
| 0 | 1.11 | 1.1100 | 0.0000 | 1.3000 | -17.1171 | 1.5400 | -38.7387 | 1.1100 | 0.0000 | 15 | 1.45 | 1.7211 | -18.6966 | 1.4900 | -2.7586 | 1.7300 | -19.3103 | 1.3030 | 10.1379 | 31 | 1.93 | 1.9025 | 1.4249 | 1.7400 | 9.8446 | 1.9600 | -1.5544 | 2.0797 | -7.7565 | 43 | 2.08 | 2.0823 | -0.1106 | 1.9500 | 6.2500 | 2.1400 | -2.8846 | 2.0535 | 1.2740 | 57 | 2.52 | 2.2209 | 11.8690 | 2.2200 | 11.9048 | 2.3900 | 5.1587 | 2.4648 | 2.1905 | 71 | 2.92 | 2.4326 | 16.6918 | 2.5400 | 13.0137 | 2.6600 | 8.9041 | 2.8516 | 2.3425 | 84 | 3.20 | 2.7052 | 15.4625 | 2.8700 | 10.3125 | 2.9300 | 8.4375 | 3.2343 | -1.0719 | 127 | 3.96 | 3.2512 | 17.8990 | 4.2900 | -8.3333 | 4.0800 | -3.0303 | 4.0055 | -1.1490 |
|
|