The measured values of C14~C23 measuring points.
| Measuring points | L/m | Measured values/mm | 630 kN | 1,050 kN | 1,155 kN | 1,365 kN | 1,575 kN | 1,785 kN | 1,890 kN |
| C14 | 585.00 | 7.61 | 9.47 | 9.82 | 9.99 | 10.50 | 10.38 | 10.41 | C15 | 615.00 | 18.98 | 23.55 | 24.76 | 27.17 | 30.49 | 32.11 | 34.15 | C16 | 645.00 | 7.03 | 7.42 | 8.16 | 8.53 | 9.06 | 9.25 | 9.35 | C17 | 705.00 | 8.04 | 12.30 | 12.64 | 13.33 | 14.02 | 16.45 | 17.01 | C18 | 735.00 | 16.48 | 24.67 | 25.34 | 28.77 | 31.48 | 33.20 | 34.25 | C19 | 765.00 | 4.18 | 6.01 | 8.05 | 9.68 | 10.03 | 11.45 | 11.45 | C20 | 825.00 | 11.92 | 14.90 | 15.06 | 15.37 | 16.73 | 17.88 | 18.01 | C21 | 855.00 | 25.30 | 31.33 | 33.27 | 37.15 | 42.78 | 45.18 | 47.23 | C22 | 885.00 | 11.05 | 15.81 | 16.29 | 17.88 | 19.45 | 21.57 | 21.60 | C23 | 952.50 | 6.09 | 7.14 | 7.83 | 8.06 | 8.24 | 8.26 | 8.45 |
|
|