Research Article

Simulation-Based Hardware Verification with a Graph-Based Specification

Table 3

Code coverage comparison between the semiformal method and CRT method.

DesignVectorCode coverage
The semiformal methodCRT method
BC%EC%TC%/FC%BC%EC%TC%/FC%

FPU10062.444.274.3/-57.840.868.2/-
40079.667.991.2/-68.558.284.0/-
90095.679.595.1/-89.474.792.4/-

MAC10069.756.472.8/-64.751.770.1/-
40082.177.289.6/-78.269.383.2/-
90097.086.892.1/-95.184.188.7/-

DMA90087.685.7-/92.475.170.4-/89.8
210092.892.3-/95.185.989.5-/94.9
480096.2100-/10096.298.7-/100

XMC90090.886.2-/93.586.281.5-/91.4
210094.796.4-/96.292.093.9-/95.7
480097.3100-/10097.3100-/100