Research Article

Health Status Assessment for Wind Turbine with Recurrent Neural Networks

Table 8

Performance criterions of the ELMAN for wind turbine 2.

SCADA variablesRMSEMAEBIASSDE

Generator speed0.3140.175-0.1510.262
Generator temperature0.0880.0670.040.088
Generator cooling air temperature0.1260.1030.220.124
Generator bearing temperature0.3140.2880.2880.123
Gearbox temperature0.210.1220.0170.031
Gearbox bearing temperature0.2150.155-0.150.154
Rotor speed0.2940.18-0.1480.249
Battery box temperature0.270.2620.2620.067
Hydraulic pressure0.3430.320.320.122
Shaft bearing temperature0.2070.19-0.1890.086
Top box temperature0.3710.3640.3640.072