Research Article
Parameter Optimization and Prediction Model of Induction Heating for Large-Diameter Pipe
Table 9
Errors between the numerical simulation and regression model prediction.
| Current Frequency (Hz) | Current Density (A/m2) | Air Gap (mm) | Outer Wall Temperature T (°C) | Simulation | Return | Error |
| 1200 | 6×107 | 30 | 883 | 920.1 | 4.2% | 1500 | 6×107 | 30 | 1043 | 1077.6 | 3.2% | 1000 | 5.5×107 | 30 | 640 | 660.5 | 3.1% | 800 | 6×107 | 30 | 683 | 710.1 | 4.0% | 1000 | 6×107 | 40 | 626 | 643.2 | 2.7% |
|
|