Research Article

Synchronization Reliability Evaluation Method for Mechanisms with Different Time Distribution

Table 6

Distribution types and parameters of the influence factors.

No.VariablesMeaningDistribute typeMean valueStandard deviation

1PMax Pressure /MPaNormal271
2DOrificing radius /mmNormal0.60.00667
3Friction coefficientNormal0.40.01
4Friction coefficientNormal0.150.01667
5Force coefficientNormal10.05
6Moment coefficientNormal10.1