Research Article

Hysteretic Behaviour of Stockbridge Dampers: Modelling and Parameter Identification

Table 3

Constitutive parameters of the cross-sectional hysteretic model for the prototype sections in the far-field and boundary layer regions of the messenger cable.

(Nm2) (Nm2) (m−1) × 10−2

“Far-field” section252.53.011
“Boundary-layer” section405.015.011