Research Article
A New Calculating Method of Pressure Response Time of Pneumatic Brake Pipe Based on Experiments
Table 3
Experimental data for comparing sequence and reference sequence.
| No. | d/mm | L/m | C/dm3/(s·bar) | p0/MPa | p/MPa | t/ms |
| 1 | 12 | 20 | 4 | 0.1 | 0.4 | 386 | 2 | 8 | 12.5 | 2.5 | 0.2 | 0.525 | 170 | 3 | 12 | 5 | 4 | 0.3 | 0.65 | 59 | 4 | 10 | 12.5 | 2.5 | 0.2 | 0.65 | 229 | 5 | 10 | 12.5 | 2.5 | 0.3 | 0.525 | 170 | 6 | 12 | 20 | 4 | 0.3 | 0.65 | 301 | 7 | 8 | 5 | 1 | 0.3 | 0.65 | 110 | 8 | 12 | 20 | 4 | 0.3 | 0.4 | 196 | 9 | 8 | 20 | 4 | 0.1 | 0.4 | 345 | 10 | 8 | 20 | 4 | 0.3 | 0.4 | 181 |
|
|