Research Article
Experimental Investigation on the Release Rule of the Gas Expansion Potential of Loaded Water-Filled Soft Coal
Table 3
Experimental data of the expansion energy release experiment under the conditions of different water contents and adsorption pressures.
| Moisture (%) |
| 4.50 | Adsorption (MPa) | 0.609 | 0.642 | 0.662 | 0.694 | 0.708 | 0.728 | 0.755 | 0.783 | 0.842 | 0.892 | Piston (m) | 0.69 | 0.77 | 0.82 | 0.84 | 0.86 | 0.57 | 0.74 | 0.80 | 0.97 | 1.05 | Conclusion | No | No | No | No | No | Yes | Yes | Yes | Yes | Yes | Coal output (kg) | — | — | — | — | — | 0.35 | 0.46 | 0.467 | 0.474 | 0.481 |
| | 4.80 | Adsorption (MPa) | 0.632 | 0.692 | 0.745 | 0.76 | 0.762 | 0.789 | 0.813 | 0.852 | 0.886 | 0.902 | Piston (m) | 0.66 | 0.77 | 0.83 | 0.83 | 0.84 | 0.48 | 0.57 | 0.69 | 0.79 | 0.81 | Conclusion | No | No | No | No | No | Yes | Yes | Yes | Yes | Yes | Coal output (kg) | — | — | — | — | — | 0.26 | 0.35 | 0.38 | 0.421 | 0.452 |
| | 5.10 | Adsorption (MPa) | 0.694 | 0.756 | 0.785 | 0.806 | 0.815 | 0.822 | 0.838 | 0.856 | 0.876 | 0.899 | Piston (m) | 0.71 | 0.80 | 0.80 | 0.81 | 0.77 | 0.27 | 0.37 | 0.37 | 0.47 | 0.53 | Conclusion | No | No | No | No | No | Yes | Yes | Yes | Yes | Yes | Coal output (kg) | — | — | — | — | — | 0.28 | 0.32 | 0.35 | 0.39 | 0.385 |
| | 5.40 | Adsorption (MPa) | 0.725 | 0.753 | 0.796 | 0.823 | 0.856 | 0.884 | 0.895 | 0.923 | 0.933 | 0.949 | Piston (m) | 0.74 | 0.79 | 0.82 | 0.82 | 0.79 | 0.23 | 0.32 | 0.42 | 0.47 | 0.55 | Conclusion | No | No | No | No | No | Yes | Yes | Yes | Yes | Yes | Coal output (kg) | — | — | — | — | — | 0.22 | 0.28 | 0.36 | 0.38 | 0.39 |
|
|