Research Article
3D Temperature Distribution Reconstruction in Furnace Based on Acoustic Tomography
Table 1
RQ of reconstructed models for three kinds of temperature distribution.
| Model | RQ | RBF | RBF-PR |
| One-peak symmetrical temperature distribution | Emax (%) | 29.45 | 0.47 | Emean (%) | 3.93 | 0.34 | Erms (%) | 4.59 | 0.37 | Ep (m) | 0 | 0 | Ehot (%) | 1.02 | 0 |
| One-peak asymmetrical temperature distribution | Emax (%) | 27.28 | 0.33 | Emean (%) | 3.60 | 0.26 | Erms (%) | 4.54 | 0.38 | Ep (m) | 0.1 | 0 | Ehot (%) | 5.07 | 0.11 |
| Two-peak temperature distribution | Emax (%) | 28.28 | 1.31 | Emean (%) | 3.32 | 0.73 | Erms (%) | 3.87 | 1.11 | Ep (m) | 0.57, 0.57 | 0, 0 | Ehot (%) | 1.67, 1.67 | 2.41, 2.41 |
|
|