Table of relation between the thickness of the PM and torque (g=0.004m).
| ā | s | | Analytical | 3D FEM | 2% | 4% | 6% | 2% | 4% | 6% |
| 0.026 | 1306 | 2121 | 2421 | 1240 | 2030 | 2334 |
| 0.028 | 1353 | 2202 | 2521 | 1279 | 2096 | 2431 |
| 0.03 | 1396 | 2275 | 2610 | 1332 | 2158 | 2522 |
| 0.032 | 1435 | 2346 | 2692 | 1372 | 2235 | 2600 |
| 0.034 | 1470 | 2406 | 2772 | 1406 | 2310 | 2681 |