Research Article

A Real-Time Reliable Condition Assessment System for 500kV Transmission Towers Based on Stress Measurement

Table 1

Measurement stress data samples and corresponding reliability indices.

Dti(MPa)Dt1Dt2Dt3Dt4βiΦ(i)

Section A127.20127.20-158.20-158.202.614.531
Section B121.63121.63-146.80-146.802.921.811
Section C103.32103.32-108.76-132.263.320.4671