Research Article
Speed Simulation of Pig Restarting from Stoppage in Gas Pipeline
Table 2
Simulations of the maximum speed of pig restarting from a stoppage using RSM.
| Run number | Gas pressure [bar] | Obstruction [bar] | Maximum pig speeds of restarting it in different ways [m/s] | By increasing inlet pressure | By decreasing outlet pressure | By increasing inlet pressure together with decreasing outlet pressure |
| 1 | 80 | 2 | 4.53 | 4.65 | 4.57 | 2 | 20 | 8 | 53.80 | 73.60 | 65.72 | 3 | 20 | 2 | 16.78 | 18.02 | 17.30 | 4 | 80 | 5 | 11.15 | 11.55 | 11.42 | 5 | 50 | 2 | 7.33 | 7.58 | 7.12 | 6 | 80 | 8 | 16.60 | 16.90 | 16.82 | 7 | 20 | 5 | 37.50 | 45.00 | 41.41 | 8 | 50 | 5 | 17.15 | 18.50 | 17.83 | 9 | 50 | 8 | 25.85 | 28.88 | 27.65 |
|
|