Research Article
Operation of Parallel Inverters in Microgrid Using New Adaptive PI Controllers Based on Least Mean Fourth Technique
Table 3
Parameters of the proposed adaptive and regular PI controllers for negative loop.
| Parameters | Value |
| Adaptive PI controller of d-axis in current loop | | = 2e-4 | | = 0.00125 | | = 0.75 | | = 7.5e-3 | | = 0 | | = 5.25 | | = 5 |
| Adaptive PI controller of q-axis in current loop | | = 1.05e-4 | | = 0.7 | | = 0.000125 | | = 7.5e-5 | | = 0 | | = 5.25 | | = 5 |
| Regular PI controller of d-axis in voltage control | | = 0.0625 | | = 0.5 |
| Regular PI controller of q-axis in voltage control | | = 0.0625 | | = 0.5 |
|
|