Research Article
Operation of Parallel Inverters in Microgrid Using New Adaptive PI Controllers Based on Least Mean Fourth Technique
Table 6
Parameters of sliding mode and regular PI controllers for positive loop.
| Parameters | Value |
| Sliding mode controller of d-axis in current loop | | = 100 | | = 0.8 | | = 0.8 | | = 20 |
| Sliding mode controller of q-axis in current loop | | = 81 | | = 0.8 | | = 0.8 | | = 20 |
| Regular PI controller of d-axis in voltage control | | = 0.0625 | | = 0.5 |
| Regular PI controller of q-axis in voltage control | | = 0.0625 | | = 0.5 |
|
|