THD values with different methods.
| THD Values | Different Simulation Time | Without APF | 0.05s | 0.1s | 0.15s |
| Different Methods | Fractional-order PID and ADRC | 24.71% | 1.67% | 2.62% | 1.63% | Double-loop PID | 24.71% | 1.98% | 4.18% | 1.70% |
|
|