Research Article

An Effective Inverse Procedure for Identifying DEMParameters of Rock-Like Materials

Table 7

Test design sampling points.

NumberInputOutput
E (GPa) (MPa)E (GPa)υσ (MPa)

120.032.8946.3035.690.300151.51
226.002.8238.2445.960.296130.68
329.182.6931.6452.030.287112.44
427.861.4734.8556.230.180141.35
521.512.1932.3240.110.252122.16
623.741.0235.3451.750.113144.75
725.231.9239.1948.210.231146.14
829.411.5941.2658.330.196157.21
921.181.3639.9343.440.167154.29
1028.991.4448.6258.740.178171.32
1127.611.8440.4053.190.223151.91
1224.091.2249.0350.550.146166.59
1321.842.2242.4240.470.256155.95
1424.951.9849.4947.320.236175.91
1525.552.4933.5846.150.273119.42
1620.802.5744.8237.420.281150.32
1726.942.3436.0449.560.264131.45
1822.091.0843.3547.530.123164.02
1924.591.1845.8751.960.140161.53
2026.031.6331.2451.550.200123.04
2122.582.0334.2042.800.240129.44
2223.082.4333.2742.120.270118.80
2327.271.7442.9853.130.213162.00
2422.902.7847.6540.560.294156.60
2528.642.6536.7651.360.284130.21
2629.812.9947.0152.050.305152.77
2728.112.0744.4052.830.244160.83
2823.481.6930.2246.130.207118.06
2926.521.3041.5154.970.159161.21
3020.452.2937.6537.660.261135.05