Research Article

ECC Design Based on Uniform Design Test Method and Alternating Conditional Expectation

Table 11

Test results for adjusted uniform designed ECC mix proportions.

No.CementFly ashw/cFiberQuartz sandWater-reducing admixtureft (MPa)ɛcu (%)GF (N·m−1)fc (MPa)

110.110.420.022410.0122.31.91087.1549.67
210.430.510.00750.80.0094.20.6648.8454.33
310.750.680.0410.60.0134.42.21936.8531.33
411.071.110.03581.60.0012.52826.8423.73
511.390.590.00490.60.0155.50.24309.2168.67
611.721.030.05510.70.0013.42.42234.0130.33
712.040.770.02890.90.0142.90.4234.0848.00
812.360.940.000010.0164.40.0147.6932.00
912.680.850.05860.80.0222.51.81414.0348.33
1013.001.200.03051.20.0141.41.5880.4633.67