Research Article
A Modeling Method of Stochastic Parameters’ Inverse Gauss Process Considering Measurement Error under Accelerated Degradation Test
Table 5
Comparison of three models in SSADT.
| Model | | | | | | | Log-LF | AIC | MTTF/h |
| Real | -2.172 | 1.342 | 1.415 | 2.716 | 0.623 | 0.050 | -184.951 | 381.902 | 10362.514 | M0 | -2.041 | 1.423 | 1.191 | 2.842 | 0.584 | 0.046 | -190.514- | 393.028 | 10410.325 | M1 | -2.304 | 1.418 | 1.251 | 2.638 | 0.715 | — | -198.230 | 406.460 | 10223.514 | M2 | -2.410 | 1.806 | — | — | 0.493 | 0.068 | -204.244 | 416.488 | 10537.241 |
|
|