The stress relaxation data.

TemperatureIDStress Relaxation/%

65°C12.122.73.524.255.556.126.757.227.688.469.46
22.293.244.164.865.746.857.48.149.2510.55
32.43.614.355.095.57.038.248.819.62910.2711.11
42.313.485.516.27.317.968.579.0710.4611.4812.31
53.144.335.927.228.149.079.4410.0911.212.7713.51
63.595.555.927.688.6110.3711.1112.2213.5114.1615

85°C72.774.625.836.668.0510.6111.211.9813.3315.64
83.884.376.297.779.169.910.3712.7714.7216.8
93.184.536.948.148.7910.0911.1114.7216.4718.66
103.614.376.297.879.3511.4812.413.715.3718.51
113.424.257.318.6110.1812.0313.715.2717.2219.25
125.275.928.059.8112.413.2415.8317.5920.0923.51

100°C134.255.188.339.5311.4813.1415.1516.9418.0519.44
144.816.167.689.2510.3712.41516.218.2420.09
155.097.038.3310.3712.2214.3516.1118.719.7221.66
164.817.59.1610.5513.5115.5516.5719.0720.2722.4
175.646.578.6112.514.4416.5718.721.222.5924.07
184.728.1410.1812.415.0917.2219.1621.5724.3526.2