Research Article
Robust Day-Ahead Dispatch for Integrated Power-Heat-Gas Microgrid considering Wind Power Uncertainty
Table 6
Optimization results under different uncertain budget.
| Uncertain budget | Γ = 0 | Γ = 8 | Γ = 16 | Γ = 24 | Mean | Max | Mean | Max | Mean | Max | Mean | Max |
| Day-ahead operation cost ($) | 13165.8 | 13196.2 | 13233.1 | 13260.2 |
| Day-ahead operation cost ($) | Cost of gas | 13343.3 | 13255.3 | 13149.6 | 13071.6 | Cost of FC | 2345.1 | 2463.5 | 2606.2 | 2711.3 | Cost of grid | −2.522.7 | −2522.7 | −2522.7 | −2522.7 | Cost of wind curtailment | 0 | 0 | 0 | 0 |
| Adjustment cost ($) | 241.6 | 473.4 | 158.9 | 322.0 | 129.7 | 360.2 | 121.1 | 313.5 |
| Total cost ($) | 13407.4 | 13639.2 | 13355.1 | 13518.2 | 13362.8 | 13593.3 | 13381.1 | 13573.7 |
|
|