Research Article
Robust Day-Ahead Dispatch for Integrated Power-Heat-Gas Microgrid considering Wind Power Uncertainty
Table 8
Optimization results with different forecasted error.
| Forecasted error | Error = 5% | Error = 10% | Error = 15% | Error = 20% | Mean | Max | Mean | Max | Mean | Max | Mean | Max |
| Day-ahead operation cost ($) | 13180.9 | 13196.2 | 13211.2 | 13226.2 |
| Day-ahead operation cost ($) | Cost of gas | 13298.8 | 13255.3 | 13211.2 | 13166.0 | Cost of FC | 2404.8 | 2463.5 | 2522.6 | 2582.9 | Cost of grid | −2522.7 | −2522.7 | −2522.7 | −2522.7 | Cost of wind curtailment | 0 | 0 | 0 | 0 |
| Adjustment cost ($) | 81.5 | 189.8 | 158.9 | 322.0 | 271.7 | 630.5 | 358.4 | 648.7 |
| Total cost ($) | 13262.4 | 13370.7 | 13355.1 | 13518.2 | 13482.9 | 13841.7 | 13584.6 | 13874.9 |
|
|