Research Article

Mathematical Analysis of Heat Transfer in Peristaltic Transport through a Rough Nonuniform Inclined Channel

Table 1

Temperature distribution at different values of angle of inclination and surface roughness parameter.


011110000
0.20.82820.82760.82710.82660.19190.19280.19340.1941
0.40.65560.65430.65340.65240.38290.38470.38600.3873
0.60.48000.47790.47640.47490.57090.57350.57540.5773
0.80.29760.29460.29250.29020.75220.75550.75770.7602
1.00.10350.09920.09620.09300.92170.92530.92770.9304

011110000
0.20.92030.91730.91530.91320.28390.28250.28160.2807
0.40.83190.82610.82220.81790.55920.55660.55480.5529
0.60.71270.70430.69860.69240.80360.79990.79750.7948
0.80.52560.51510.50800.50030.98010.97600.97320.9702
1.00.21860.20700.19920.19081.03681.03311.03071.0282

011110000
0.21.06171.05651.05291.04910.42540.42170.41920.4166
0.41.10291.09251.08551.07790.83020.82300.81810.8129
0.61.07041.05531.04511.03411.16131.15101.14401.1365
0.80.87590.85690.84400.83031.33041.31781.30931.3002
1.00.39560.37430.35980.34441.21381.20041.19141.1818