Research Article
Optimization of the Accelerated Degradation Test Plan for Electrical Connector Contact Pairs Based on a Nonlinear Wiener Process
Table 1
The optimal design plan of stress level
.
| The optimal design plan of stress level | Temperature stress T (°C) | Sample distribution ratio | Test frequency () | Specific test time t (h) | Variance factor |
| 119 | 0.571 | 1.9 | 6.86 | 0.89 | 54.88 | 185.22 | | 5000 | 138 | 0.132 | 0.81 | 0.53 | 4.24 | 14.31 | | 4908.33 | 158 | 0.296 | 0.81 | 0.53 | 4.24 | 14.31 | | 4908.33 |
|
|