Research Article

Optimization of the Accelerated Degradation Test Plan for Electrical Connector Contact Pairs Based on a Nonlinear Wiener Process

Table 4

: constant stress accelerated degradation test plan.

The optimal test planThe traditional test plan
Temperature stress T (°C)Sample distribution ratioTest frequency ()Variance factor Temperature stress T (°C)Sample distribution ratioTest frequency ()Variance factor

1190.5711.90.891050.3332.291.03
1380.1320.811300.3332.29
1580.2960.811580.3332.29