Research Article
Electromagnetic Forces and Mechanical Responses of Stator Windings before and after Rotor Interturn Short Circuit in Synchronous Generators
Table 3
The maximum of deformation and stress of each winding.
| ā | Deformation (10ā7m)/time (s) | Tendency | Stress (104pa)/time (s) | Tendency |
| Winding 1 | Normal | 9.187/0.0385 | Increase | 5.974/0.0620 | Decrease | RISC | 9.188/0.0385 | 5.928/00385 |
| Winding 2 | Normal | 2.1138/0.0555 | Decrease | 2.508/0.002 | Increase | RISC | 2.1129/0.0555 | 2.818/0.002 |
| Winding 3 | Normal | 719.3/0.0380 | Increase | 540/0.0380 | Increase | RISC | 736.3/0.0380 | 554/0.038 |
|
|