Research Article

Numerical Study of Electromagnetic Loss and Heat Transfer in an Oil-Immersed Transformer

Table 3

Hot spot temperatures for different regions with different computational grids.

Total grid numbersRegionsMaximal grid size (cm)Minimal grid size (cm)Grid numbersHot spot (K)Extrapolated value (K)GCI number (%)

923 456Core5.831.6741 736383.38366.790.9
Coil3.141.1444 712
Metal component6.011.0641 746
Oil15.041.01795 262
1 812 723Core5.441.2578 400373.45
Coil2.111.0183 040
Metal component4.871.1699 138
Oil14.010.951 552 145
3 560 081Core5.241.00195 172369.46
Coil1.900.86149 100
Metal component4.870.78195 745
Oil11.110.723 020 064