Research Article

Multiobjective Optimized Dispatching for Integrated Energy System Based on Hierarchical Progressive Parallel NSGA-II Algorithm

Table 3

The parameters of energy supply equipment.

EquipmentParametersValues

Capstone C1000 microturbine systemMaximum power generated 1000 kW
Rated efficiency 0.33
Waste heat boilerMaximum power input 2000 kW
Rated efficiency 0.8
Lithium bromide absorption refrigeration unitMaximum power input 2000 kW
Coefficient of performance 1.2
Gas boilerMaximum power input 1000 kW
Rated efficiency 0.9
Electric refrigeratorMaximum power input 500 kW
Coefficient of performance 4.0
Household air conditionerMaximum power input 1000 kW
Energy efficiency ratio 2.6
Coefficient of performance 3.1
Public gridMaximum power exchange 1500 kW
Photovoltaic cellsMaximum power generated 187.8 kW