Research Article
The Liquid Maldistribution Analysis of the Trickle Bed Reactor with the CFD Method
Table 2
Comparison of normalized average values.
| Section (flow rate) | 3.4 mm | 5.3 mm | CFD (–) | ERT (–) | Error (%) | CFD (–) | ERT (–) | Error (%) |
| P1 (300 ml/min) | 0.25 | 0.25 | 0.67 | 0.24 | 0.22 | 11.88 | P2 (300 ml/min) | 0.26 | 0.38 | 30.29 | 0.24 | 0.33 | 29.30 | P3 (300 ml/min) | 0.24 | 0.44 | 45.18 | 0.24 | 0.35 | 31.66 | P4 (300 ml/min) | 0.23 | 0.45 | 48.68 | 0.23 | 0.42 | 44.75 | P1 (700 ml/min) | 0.58 | 0.44 | 24.68 | 0.65 | 0.39 | 40.53 | P2 (700 ml/min) | 0.59 | 0.65 | 9.02 | 0.63 | 0.60 | 5.26 | P3 (700 ml/min) | 0.56 | 0.73 | 22.84 | 0.60 | 0.64 | 5.60 | P4 (700 ml/min) | 0.54 | 0.80 | 32.63 | 0.49 | 0.77 | 35.90 | P1 (1100 ml/min) | 0.94 | 0.57 | 39.57 | 0.95 | 0.52 | 44.76 | P2 (1100 ml/min) | 1 | 0.83 | 17.37 | 0.99 | 0.82 | 17.46 | P3 (1100 ml/min) | 0.95 | 0.91 | 4.45 | 1 | 0.86 | 14.38 | P4 (1100 ml/min) | 0.86 | 1 | 13.99 | 0.90 | 1 | 9.58 |
| Correlation coefficient | 0.7686 | 0.7647 |
|
|