Research Article

Error Distribution of a 5-Axis Measuring Machine Based on Sensitivity Analysis of Geometric Errors

Table 7

The distributed error range of the crucial geometric errors.

Geometric error itemReduced by (%)Distributed error range

h10, h13, h27, h3420±4″
h1140±3″
h6, h2950±2.5″
h4, h26, h2860±2″
h570±1.5″