Research Article

On the Nonlinear Seismic Responses of Shock Absorber-Equipped Porcelain Electrical Components

Table 3

Shock absorption efficiency with different values of γ and magnitudes of seismic excitation.

Seismic excitation (g)Shock absorption efficiency (%)
γ = 3000γ = 4000γ = 5000γ = 6000γ = 7000

0.119.1820.8122.8025.0727.56
0.226.2931.2936.0042.1247.21
0.335.9743.8051.5057.2562.24
0.445.6054.7162.0067.4271.60
0.553.8663.0269.4774.0776.90