Research Article

An Integrated Method for Fire Risk Assessment in Residential Buildings

Table 6

Detailed scoring rules of U15 and U4.

IndexesDetailed scoring rulesScore (L)Score (S)Remarks

U15-building service life(1) 0 < service life < n/5
(2) n/5 < service life ≤ 2n/5
(3) 2n/5 < service life ≤ 3n/5
(4) 3n/5 < service life ≤ 4n/5
(5) Service life < 4n/5
(0.00, 0.00, 0.25)
(0.00, 0.25, 0.50)
(0.25, 0.50, 0.75)
(0.50, 0.75, 1.00)
(0.75, 1.00, 1.00)
(0.00, 0.00, 0.25)
(0.00, 0.25, 0.50)
(0.25, 0.50, 0.75)
(0.50, 0.75, 1.00)
(0.75, 1.00, 1.00)
n is the design life
U4-property fire management(1) Four aspects are perfect
(2) Any aspects are not perfect
(3) All four aspects are not perfect
(0.25, 0.50, 0.75)
(0.25, 0.50, 0.75)
(0.50, 0.75, 1.00)
(0.25, 0.50, 0.75)
(0.25, 0.50, 0.75)
(0.50, 0.75, 1.00)
Including four aspects:
(1) There are full-time fire safety management personnel with prejob training
(2) The system of fire management is established, and the responsibility is clear
(3) The hidden danger is checked and recorded every day
(4) Regular inspection of fire facilities and timely maintenance