Variation characteristic in the ultrasonic shear pulse velocity of three kinds of concrete under FT cycles.

SpecimenVS at 0 FT cycles (km/s)VS at 300 FT cycles (km/s)Decay rate of VS (%)

C40-A1-NCTC2.842.1823.33
C40-A2-NCTC2.841.9730.49
C40-A3-NCTC2.862.3119.29