Research Article
Computational Method and Simulation of Reliability for Series, Parallel, and k-Out-of-n Systems with Interval Parameters
Table 4
Parameters of the hollow cylindrical cantilever beam.
| Variable | Distribution | Parameter 1 | Parameter 2 |
| t (mm) | Normal | 5 | 0.1 | d (mm) | Normal | 42 | 0.5 | L2 (mm) | Uniform | 59.75 | 60.25 | F1 (N) | Gumbel | 3000 | 300 | F2 (N) | Gumbel | 3000 | 300 | P (N) | Normal | 12000 | 1200 | T (Nm) | Normal | 90 | 9 | L1 (mm) | Interval | 119.75 | 120.25 | Θ1 (°) | Interval | 0 | 10 | Θ2 (°) | Interval | 5 | 15 | U (MPa) | Normal | 300 | 30 | S (MPa) | Normal | 200 | 20 | Θ (°) | Interval | 0 | 1.9 | τ (MPa) | Normal | 100 | 10 | (mm) | Interval | 0.10 | 0.18 |
|
|