Research Article

Computational Method and Simulation of Reliability for Series, Parallel, and k-Out-of-n Systems with Interval Parameters

Table 4

Parameters of the hollow cylindrical cantilever beam.

VariableDistributionParameter 1Parameter 2

t (mm)Normal50.1
d (mm)Normal420.5
L2 (mm)Uniform59.7560.25
F1 (N)Gumbel3000300
F2 (N)Gumbel3000300
P (N)Normal120001200
T (Nm)Normal909
L1 (mm)Interval119.75120.25
Θ1 (°)Interval010
Θ2 (°)Interval515
U (MPa)Normal30030
S (MPa)Normal20020
Θ (°)Interval01.9
τ (MPa)Normal10010
(mm)Interval0.100.18