Mechanical parameters of T700/T009 material.

DirectionElastic modulusTensile strengthCompressive strength

Direction 1 (MPa)1400002616965
Direction 2 (MPa)900047168
Direction 3 (MPa)900047124
DirectionShear modulusShear strengthPoisson’s ratio
1-2 face (MPa)4700720.32
2-3 face (MPa)3100510.45
1-3 face (MPa)4700710.32
Density (g/cm3)1.61Single-layer thickness/mm0.2